方案
By Technology
The MC33035 is a high performance second generation monolithic brushless DC motor controller containing all of the active functions required to implement a full featured open loop, three or four phase motor control system. This device consists of a rotor position decoder for proper commutation sequencing, temperature compensated reference capable of supplying sensor power, frequency programmable sawtooth oscillator, three open collector top drivers, and three high current totem pole bottom drivers ideally suited for driving power MOSFETs.
Also included are protective features consisting of undervoltage lockout, cycle-by-cycle current limiting with a selectable time delayed latched shutdown mode, internal thermal shutdown, and a unique fault output that can be interfaced into microprocessor controlled systems.
Typical motor control functions include open loop speed, forward or reverse direction, run enable, and dynamic braking. The MC33035 is designed to operate with electrical sensor phasings of 60° /300° or 120° /240° , and can also efficiently control brush DC motors.
搜寻
Close Search
产品:
2
分享
排序方式
产品系列:
┗
可订购器件:
2
产品
状态
CAD Models
Compliance
Package Type
Case Outline
MSL Type
MSL Temp (°C)
Container Type
Container Qty.
ON Target
Phase
VM Min (V)
VM Max (V)
VCC Min (V)
VCC Max (V)
IO Max (A)
IO Peak Max (A)
Control Type
Reference Price
More Details
NCV33035DWR2G
More Details
Show More
1-25 of 25
Products per page
Jump to :
Find and compare products, get support and connect with onsemi sales team.
Contact Sales
分享
导出
Rows
Printer Friendly Version
PDF Format
Excel Format
CSV Format
To proceed order you need to accept Terms
可靠性数据
Die Related Summary Data
Device: NCV33035DWR2G
Equivalent to wafer fab process: BP STD LINEAR
产品技术
产品技术
等效器件小时
平均故障间隔时间/平均无故障时间(按小时计算)
FITS
BP STD LINEAR
10
12120914040
More Details
Re-calculate Data
Data is based on the following assumptions.
Note: The temperature and confidence level may be adjusted to your requirements.
Disclaimer: A reliability FIT rate calculated using this tool shall not be used for any functional safety purpose. In case a raw FIT rate needs to be estimated for a component which is targeted to be used in a safety critical application (i.e. compliant to ISO 26262 standard) it should be calculated according to generic safety standards (IEC62380, IEC61709, SN29500, FIDES, etc.)