方案
By Technology
NCP12510 是一款高度集成的 PWM 控制器,能够在极小型 TSOP-6 封装内提供耐用的高性能离线电源。该控制器供电电压范围高达 35 V,具有带抖动的 65 kHz 或 100 kHz 开关电路,在峰值电流模式控制下运行。当辅助侧功率开始降低时,该控制器将其开关频率自动折回至最低 26 kHz 的水平。当功率进一步下降时,该零部件进入跳过周期,同时对峰值电流进行限制。该控制器具有集成保护功能,如过功率保护 (OPP)、过电压保护 (OVP) 和短路保护。NCP12510 是基于受欢迎的反激控制器 NCP1250 进行改善且引脚兼容的控制器。
搜寻
Close Search
产品:
5
分享
排序方式
产品系列:
┗
可订购器件:
5
产品
状态
CAD Models
Compliance
Package Type
Case Outline
MSL Type
MSL Temp (°C)
Container Type
Container Qty.
ON Target
Topology
Control Mode
fsw Typ (kHz)
Stand-by Mode
UVLO (V)
Short Circuit Protection
Latch
Soft Start
VCC Max (V)
Drive Cap. (mA)
Reference Price
NCP12510ASN100T1G
Active
Pb
A
H
P
TSOP-6
3
260
REEL
3000
Y
Flyback
Current Mode
100
Yes
8.3
Yes
Yes
Yes
35
300 / 500
$0.2109
More Details
NCP12510ASN65T1G
Active
Pb
A
H
P
TSOP-6
3
260
REEL
3000
Y
Flyback
Current Mode
65
Yes
8.3
Yes
Yes
Yes
35
300 / 500
$0.2118
More Details
NCP12510BSN100T1G
Active
Pb
A
H
P
TSOP-6
3
260
REEL
3000
Y
Flyback
Current Mode
100
Yes
8.3
Yes
No
Yes
35
300 / 500
$0.2057
More Details
NCP12510BSN65T1G
Active
Pb
A
H
P
TSOP-6
3
260
REEL
3000
N
Flyback
Current Mode
65
Yes
8.3
Yes
No
Yes
35
300 / 500
$0.1963
More Details
NCP12510CSN65T1G
Active
Pb
A
H
P
TSOP-6
3
260
REEL
3000
Y
Flyback
Current Mode
65
Yes
8.3
Yes
No
Yes
35
300 / 500
$0.1993
More Details
Show More
1-25 of 25
Products per page
Jump to :
Find and compare products, get support and connect with onsemi sales team.
Contact Sales
分享
导出
Rows
Printer Friendly Version
PDF Format
Excel Format
CSV Format
To proceed order you need to accept Terms
可靠性数据
Die Related Summary Data
Device: NCP12510ASN100T1G
Equivalent to wafer fab process: ONC25
产品技术
产品技术
等效器件小时
平均故障间隔时间/平均无故障时间(按小时计算)
FITS
ONC25
1
2712519294
More Details
Re-calculate Data
Data is based on the following assumptions.
Note: The temperature and confidence level may be adjusted to your requirements.
Disclaimer: A reliability FIT rate calculated using this tool shall not be used for any functional safety purpose. In case a raw FIT rate needs to be estimated for a component which is targeted to be used in a safety critical application (i.e. compliant to ISO 26262 standard) it should be calculated according to generic safety standards (IEC62380, IEC61709, SN29500, FIDES, etc.)