The NCS211R and NCV211R (AEC- Q100 qualified) are voltage output, current sense amplifiers that can measure voltage across shunts at common−mode voltages from −0.3 V to 26 V, independent of supply voltage. With a fixed gain of 500 V/V, the low offset of the zero−drift architecture enables current sensing across the shunt with maximum voltage drops as low as 10 mV full−scale. These devices can operate from a single +2.2 V to +26 V power supply, drawing a maximum of 80 µA of supply current. Available in SC70-6 packageAdditional gain options are available: NCS213R (50 V/V), NCS214R (100 V/V) , NCS210R (200 V/V)
如需购买产品或样品,请先登录您的安森美账号。
搜寻
Close Search
产品:
3
分享
排序方式
产品系列:
┗
可订购器件:
3
产品
状态
CAD Models
Compliance
Package Type
Case Outline
MSL Type
MSL Temp (°C)
Container Type
Container Qty.
ON Target
Channels
Gain (V/V)
Gain Error Max (%)
Vs Min (V)
Vs Max (V)
VCM (V)
Iq Typ (mA)
Bandwidth Typ (-3dB)
Vos Max (mV)
Vos Drift Max (µV/°C)
Operating Temperature Range (°C)
CMRR Typ (dB)
Reference Price
NCS211RMUTAG
Active
Pb
A
H
P
UQFN-10
1
260
REEL
3000
Y
1
500
±1
2.2
26
-0.3 to 26
0.04
0.025
±0.035
0.5
-40 to 125
125
$0.2855
More Details
NCS211RSQT2G
Active
Pb
A
H
P
SC-88-6 / SC-70-6 / SOT-363-6
1
260
REEL
3000
Y
1
500
±1
2.2
26
-0.3 to 26
0.04
0.025
±0.035
0.5
-40 to 125
125
$0.2703
More Details
NCV211RSQT2G
Active
Pb
A
H
P
SC-88-6 / SC-70-6 / SOT-363-6
1
260
REEL
3000
Y
1
500
±1.5
2.2
26
-0.3 to 26
0.04
0.025
±0.05
1.5
-40 to 125
135
$0.3347
More Details
Show More
1-25 of 25
Products per page
Jump to :
If you're interested to learn about this onsemi product, contact sales by filling out the form below.
向销售发送邮件
分享
导出
Rows
Printer Friendly Version
PDF Format
Excel Format
CSV Format
To proceed order you need to accept Terms
可靠性数据
Die Related Summary Data
Device: NCS211RMUTAG
Equivalent to wafer fab process: ONC25
产品技术
产品技术
等效器件小时
平均故障间隔时间/平均无故障时间(按小时计算)
FITS
ONC25
1
2712519294
More Details
Re-calculate Data
Data is based on the following assumptions.
Note: The temperature and confidence level may be adjusted to your requirements.
Disclaimer: A reliability FIT rate calculated using this tool shall not be used for any functional safety purpose. In case a raw FIT rate needs to be estimated for a component which is targeted to be used in a safety critical application (i.e. compliant to ISO 26262 standard) it should be calculated according to generic safety standards (IEC62380, IEC61709, SN29500, FIDES, etc.)
Hello, your current browser settings are preventing us from processing your submission. You can adjust your browser settings and reload the page or you can submit an email directly to inside.sales@onsemi.com
You might also try the following:
Thank you for submitting the contact sales form. Your request is on its way to our sales support team!
We thank you for your interest in onsemi and are working on your request. Our sales support team will respond to your request within two business days.