方案
By Technology
The MC10/100EP17 is a 4-bit differential line receiver based on the EP16 device. The >3.0 GHz maximum frequency provided by the high frequency outputs makes the device ideal for buffering of very high speed oscillators.
The VBB pin, an internally generated voltage supply, is available to this device only. For single-ended input conditions, the unused differential input is connected to VBB as a switching reference voltage. VBB may also rebias AC coupled inputs. When used, decouple VBB and VCC via a 0.01uF capacitor and limit current sourcing or sinking to 0.5 mA. When not used, VBB should be left open.
The design incorporates two stages of gain, internal to the device, making it an excellent choice for use in high bandwidth amplifier applications.
Inputs of unused gates can be left open and will not affect the operation of the rest of the device. All VCC and VEE pins must be externally connected to power supply to guarantee proper operation.
The 100 Series contains temperature compensation.
如需购买产品或样品,请先登录您的安森美账号。
搜寻
Close Search
产品:
1
分享
排序方式
产品系列:
┗
可订购器件:
1
产品
状态
CAD Models
Compliance
Package Type
Case Outline
MSL Type
MSL Temp (°C)
Container Type
Container Qty.
ON Target
Type
Channels
Input / Output Ratio
Input Level
Output Level
VCC Typ (V)
tJitterRMS Typ (ps)
tskew(o-o) Max (ps)
tpd Typ (ns)
tR & tF Max (ps)
fmaxClock Typ (MHz)
fmaxData Typ (Mbps)
Reference Price
MC100EP17DTG
Active, Not Rec
Pb
A
H
P
TSSOP-20
1
260
TUBE
75
Y
Signal Driver
4
1:1
CML
ECL
ECL
5
0.147
~NA~
0.22
220
3000
~NA~
Price N/A
More Details
Show More
1-25 of 25
Products per page
Jump to :
Find and compare products, get support and connect with onsemi sales team.
Contact Sales
分享
导出
Rows
Printer Friendly Version
PDF Format
Excel Format
CSV Format
To proceed order you need to accept Terms
可靠性数据
Die Related Summary Data
Device: MC100EP17DTG
Equivalent to wafer fab process: MOSAIC
产品技术
产品技术
等效器件小时
平均故障间隔时间/平均无故障时间(按小时计算)
FITS
MOSAIC
0
476668904
More Details
Re-calculate Data
Data is based on the following assumptions.
Note: The temperature and confidence level may be adjusted to your requirements.
Disclaimer: A reliability FIT rate calculated using this tool shall not be used for any functional safety purpose. In case a raw FIT rate needs to be estimated for a component which is targeted to be used in a safety critical application (i.e. compliant to ISO 26262 standard) it should be calculated according to generic safety standards (IEC62380, IEC61709, SN29500, FIDES, etc.)